Evco EVCLC33DJ2 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Evco EVCLC33DJ2. EVCO EVCLC33DJ2 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 66
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
EVCO S.p.A.
Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204
page 1 of 66
Vcolor 338 L
Controller for "top-class" electric ovens for
gastronomy and pastry, with 7 inch TFT
graphic display colour touch-screen, in split
version that can be integrated into the unit.
Installer manual | ENGLISH
Code 144VC338LE204
Przeglądanie stron 0
1 2 3 4 5 6 ... 65 66

Podsumowanie treści

Strona 1 - Vcolor 338 L

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 1 of 66 Vcolor 338 L Controller for "top-class" electri

Strona 2

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 10 of 66 2.3 Installation warnings - make sure that the device work

Strona 3

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 11 of 66 3 ELECTRIC CONNECTION 3.1 Electric connection The followin

Strona 4 - 1.1 Introduction

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 12 of 66 GND - + VDC

Strona 5

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 13 of 66 Management of the ventilation in "on/off" mode and

Strona 6

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 14 of 66 Management of the ventilation in "on/off" mo

Strona 7

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 15 of 66 Example of connection for motorized air vent cam timer, such

Strona 8

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 16 of 66 4 DESCRIPTION 4.1 Description of the user interface The fo

Strona 9

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 17 of 66 The following drawing illustrates the layout of the device u

Strona 10 - 2.3 Installation warnings

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 18 of 66 4.2 Description of the control module The following drawing

Strona 11 - 3.1 Electric connection

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 19 of 66 11 digital outputs K10... K13 12 digital output K9 13 dig

Strona 12

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 2 of 66 Important Read this document thoroughly before installa

Strona 13 - EVCO S.p.A

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 20 of 66 5 COMMISSIONING 5.1 Commissioning Operate as indicated: 1.

Strona 14

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 21 of 66 K0 Enables rotor 0 W17 Cleaning type 0 = disabled 1 = wi

Strona 15

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 22 of 66 6 MANAGEMENT OF UTILITIES 6.1 Preliminary notes This para

Strona 16 - 4 DESCRIPTION

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 23 of 66 6.8 Cooking fumes reduction The cooking fumes reduction

Strona 17

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 24 of 66 Important: with the w9=0 setting the "rinse aid" p

Strona 18

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 25 of 66 When the temperature lies within the "precleaning

Strona 19

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 26 of 66 6.10 User interface variant for ROTOR ovens management T

Strona 20 - 5.1 Commissioning

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 27 of 66 7 USER INTERFACE 7.1 Switching the device on/off Operate a

Strona 21

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 28 of 66 8 COOKING CYCLE 8.1 Preliminary notes Every cooking cycl

Strona 22

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 29 of 66 8.2 Setting the cooking cycle Operate as follows to set the

Strona 23 - 6.8 Cooking fumes reduction

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 3 of 66 Indice 1 INTRODUCTION ...

Strona 24

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 30 of 66 To select/scroll the cooking cycle phases, proceed as follow

Strona 25

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 31 of 66 8.3 Starting the cooking cycle Once the cooking cycle has b

Strona 26 - ROTOR ovens management

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 32 of 66 9 “MY COOKBOOK” FUNCTION 9.1 Preliminary notes The “MY COO

Strona 27 - 7.2 Silencing the buzzer

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 33 of 66 9.3 Starting a recipe Operate as follows to start a recipe:

Strona 28 - 8.1 Preliminary notes

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 34 of 66 The following table illustrates the factory settings of the

Strona 29 - MODIFICA VALORE

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 35 of 66 11 “FAVOURITE CYCLES” FUNCTION 11.1 Preliminary notes The

Strona 30 - RIEPILOGO CICLO

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 36 of 66 12 "WEEKLY PROGRAMMED SWITCH-ON" FUNCTION 12.1

Strona 31 - FINE COTTURA 125minfase 3/3

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 37 of 66 12.3 Enabling the "Weekly programmed switch-on"

Strona 32 - 9.2 Saving a recipe

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 38 of 66 13 OTHER FUNCTIONS 13.1 Display of the alarms status Opera

Strona 33 - 10.1 Preliminary notes

EVCO S.p.A. 14 BOILER EXPANSION 14.1 Activation of the expansionTo enable the boiler expansion EVCLE305XXE1. Enable the boiler through parameter2. S

Strona 34 - Starting a special cycle

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 4 of 66 1 INTRODUCTION 1.1 Introduction Vcolor 338 L is a controlle

Strona 35 - 11.1 Preliminary notes

EVCO S.p.A. In the BOILER menu, it will be possible to select the function Starting this cycle, the following phases will be performed1. Water charg

Strona 36

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 41 of 66 If the drain fails, the alarm “BOILER DRAIN” will be activat

Strona 37

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 42 of 66 15.3 Application scheme The burner module EVCLE302XXE i

Strona 38

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 43 of 66 15.5 Errors handling Ignition phase: If no flame is detect

Strona 39

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 44 of 66 16 CONFIGURATION16.1 Setting the time, date and day o

Strona 40

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 45 of 66 16.2 Setting the configuration parameters Operate as foll

Strona 41 - 15.2 Electrical connection

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 46 of 66 16.3 List of configuration parameters The following table i

Strona 42 - 15.4 Operation

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 47 of 66 r7 0 r8 °C/°F (2) 0 minimum delta T set-point (referring

Strona 43 - 15.5 Errors handling

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 48 of 66 PARAM. MIN. MAX. U.M. DEF. FAN F0 0 3 - - - 0 type

Strona 44 - 16 CONFIGURATION

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 49 of 66 t3 0 999 s 60 injection delay of the steam generated in

Strona 45

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 5 of 66 1.2 Summary table of the models available, the main f

Strona 46

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 50 of 66 t12 0 500 °C/°F (2) 120 temperature above which the inje

Strona 47

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 51 of 66 A1 0 500 °C/°F (2) 0 temperature above which the max

Strona 48

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 52 of 66 u2 0 600 ds (s/10) 120 air vent output inhibition du

Strona 49

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 53 of 66 w1 1 99 °C/°F (2) 10 hysteresis authorisation for precl

Strona 50

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 54 of 66 PARAM. MIN. MAX. U.M. DEF. BURNERS b0 2500 6000 RPM

Strona 51

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 55 of 66 17 USE OF THE USB PORT 17.1 Preliminary information Throug

Strona 52

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 56 of 66 18 ALARMS 18.1 Alarms A buzzer is activated if an alarm oc

Strona 53

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 57 of 66 No connection ALARM user interface-control module communicat

Strona 54

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 58 of 66 Minimum boiler water level ALARM minimum boiler water level

Strona 55

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 59 of 66 19 ACCESSORIES 19.1 Optoisolated RS-485/USB serial interfa

Strona 56 - 18.1 Alarms

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 6 of 66 Configurable (fan right rotation default) (1) 1 A Configurab

Strona 57

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 60 of 66 20 TECHNICAL DATA 20.1 Technical data Purpose of the comma

Strona 58

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 61 of 66 Rated impulse voltage: 4 KV. Overvoltage category: III. Cl

Strona 59 - 19 ACCESSORIES

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 62 of 66 digital inputs for high voltage contact Power supply: 230 VA

Strona 60 - 20.1 Technical data

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 63 of 66 Communication port: 2 ports: - 1x RS-485 MODBUS port - 1x U

Strona 61

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 64 of 66

Strona 62

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 65 of 66 Vcolor 338 L Controller for "top-class" electri

Strona 63

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 66 of 66 EVCO S.p.A

Strona 64

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 7 of 66 The following table illustrates the purchase codes. Purchase

Strona 65

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 8 of 66 2 DIMENSIONS AND INSTALLATION 2.1 User interface dimensions

Strona 66

EVCO S.p.A. Vcolor 338 L | Installer manual ver. 2.0 | Code 144VC338LE204 page 9 of 66 Control module dimensions and installation The following draw

Powiązane modele: EVCLC33DC2E

Komentarze do niniejszej Instrukcji

Brak uwag